Download PLX Network & Wireless Cards Driver



PLX31-EIP-ASCII4

  1. Download PLX Network & Wireless Cards Drivers
  2. Download Plx Network & Wireless Cards Driver Free
  3. Download Plx Network & Wireless Cards Driver Windows 10
  4. Download Plx Network & Wireless Cards Driver Download

Demo Network Performance Monitor and see firsthand how you can quickly detect, diagnose, and resolve network performance issues and outages today. Dive into SolarWinds® Network Performance Monitor (NPM), an easy-to-use, affordable network solution for the IT professionals who need scale and performance. Network Touch Screen Controllers; Network I/O Peripherals. Search EASE software and download QSC loudspeaker GLL & CLF files. EASE QSControl.net, Signal Manager. Download Firmware drivers for Windows, firmware, bios, tools, utilities.

ProSoft Technology’s EtherNet/IP™ to ASCII four-port communication gateway allows high-speed bi-directional data transfers between EtherNet/IP™-enabled PACs and ASCII devices such as weigh scales and barcode readers. The EtherNet/IP™ protocol driver supports the explicit messaging implementation. The gateway is userconfigurable as both a client and a server.

EtherNet/IP™ PACs include Rockwell Automation® ControlLogix® and CompactLogix™, as well as several Schneider Electric® controllers. Applications for this module are found in most industries, especially manufacturing, oil & gas, electrical power and food processing.

The gateway has several features that allow for simplified integration, reduced commissioning time and optimized performance.

Imágenes

Características y Beneficios

  • Data prioritization: Multiple I/O connections allow you to set RPIs for status and/or control data, optimizing Ethernet bandwidth.
  • Includes an embedded EDS Add-On Profile, allowing for simplified integration and reduced commissioning time.
  • Includes a SD card slot (SD card optional) for storing configuration files. This can be used for disaster recovery.
  • ProSoft Discovery Service: This utility allows your PC to see the gateway and change its default IP address without being on the same subnet.
  • Secure module configuration via module switch (v1.04 and greater).
  • Up to 10,000 16-bit registers can be used to exchange large amounts of data

Especificaciones

EtherNet/IP™ Specifications

Specification

Description

Number of Class 3 Server Connections

5

Supported PLC Types

PLC2, PLC5, SLC, CLX, CMPLX, MICROLX

Supported Message Types

PCCC and CIP

Class 3 Client Connections

Connected: 2
Unconnected: 1

Number of Class 1 I/O Connections

4

I/O connection sizes

248/248

Max RPI time Rec driver download.

5 ms per connection

CIP Services Supported

0x4C - CIP Data Table Read
0x4D - CIP Data Table Write
CIP Generic

Command List

Support for 100 commands per Client, each configurable for command type, IP address, register to/from addressing and word/bit count

Command Sets

PLC-2/PLC-3/PLC5 Basic Command Set
PLC5 Binary Command Set
PLC5 ASCII Command Set
SLC500 Command Set

ASCII Specifications

Transmit and Receive Buffer Size

255 byte Transmit character length with 0 to 65535 millisecond delay between each transmitted character

Hardware

Specification

Description

Power Supply

24 VDC nominal

10 to 36 VDC allowed

Positive, Negative, GND Terminals

Current Load

24 VDC nominal @ 300 mA
10 to 36 VDC @ 610 mA maximum

Operating Temperature

-25°C to 70°C (-13°F to 158°F)

Storage Temperature

-40°C to 80°C (-40°F to 176°F)

Shock

IEC 60068-2-27; 15G @ 11ms, 3-Axis (Operational)
IEC 60068-2-27; 30G @ 18ms, 3-Axis (Non-Operational)

Vibration

IEC 60068-2-6; 5G @ 10 to 150 Hz

Relative Humidity

5% to 95% RH with no condensation

Dimensions (H x W x D)

5.38 x 1.99 x 4.38 in 13.67 x 5.05 x 11.13 cm

LED Indicators

Configuration (CFG), Error (ERR), Power (PWR), Hardware Fault (FLT), Network Status (NS), EtherNet/IP™ Class I or Class III Connection Status (EtherNet/IP Only) Module Status (MS), Module Configuration Status (EtherNet/IP Only) Ethernet Communication Port Link/Activity, and 100 mbit Serial Communication Port Receive (RX) and Transmit (TX)

Ethernet Port

10/100Mbit half-duplex RJ45 Connector Electrical Isolation 1500 Vrms at 50 to 60 Hz for 60 seconds, applied as specified in section 5.3.2 of IEC 60950: 1991 Ethernet Broadcast Storm Resiliency is less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration

Number of Serial Ports

4

Serial Port Isolation

2500 Vrms port signal isolation per UL 1577 serial port communication signal uses RF (Radio Frequency) modulation signal as isolation media, IC chip model is SiliconLabs Si844x (Si8440,Si8441,Si8442)

Shipped With Each Unit

2.5 mm screwdriver
J180 Power Connector
(4) RJ45-DB9M Serial Adapter Cable (serial protocol)
(4) DB9 to Screw Terminal Adapter (serial protocol)

Download PLX Network & Wireless Cards drivers

Descargas

PLX31-EIP-ASCII4 Datasheet900,93 kBÚltima Modificación 21.12.2020
PLX30 Gateway Family FAQ569,86 kBÚltima Modificación 07.10.2020
PLX3x User Manual6,23 MBÚltima Modificación 01.12.2020
PLX30 Family CAD Files67,72 MBÚltima Modificación 09.03.2017
ProSoft Configuration Builder
Technical Note - Migrating from 5202-DFNT-ASCII4 to PLX31-EIP-ASCII41,06 MBÚltima Modificación 19.12.2019
PLX3x EDS Files 1.452,73 kBÚltima Modificación 04.01.2021

Vídeo

Download PLX Network & Wireless Cards Drivers

Quick Configuration of ProSoft's ASCII to EtherNet/IP Gateway Tutorial

Understanding Client, Server & I/O Messaging for Ethernet Networks

Download Plx Network & Wireless Cards Driver Free

Guide to bit-level data addressing in ProSoft Modbus modules

Guide to 32-bit data types in ProSoft Modbus modules

Download Plx Network & Wireless Cards Driver Windows 10

Certificaciones

Download Plx Network & Wireless Cards Driver Download

Declaration of Conformity (ATEX) 348,50 kBÚltima Modificación 28.10.2019
CB Safety 327,80 kBÚltima Modificación 31.03.2020
Korean KC Registration 974,32 kBÚltima Modificación 07.07.2020
UL/cUL; Class 1, Div 2 233,35 kBÚltima Modificación 08.04.2019
Declaration of Conformity (RoHS/CE) 359,34 kBÚltima Modificación 18.12.2020
ODVA EtherNet/IP - Declaration of Conformity 183,48 kBÚltima Modificación 09.11.2020